Amazon Hub Lockers specs & site requirements

Amazon Hub Lockers come in several sizes and have specific requirements for space, power and access. The team reviews the property details and recommends a setup that fits.

Seven door sizes

SizeDimensionsTypical use
Envelope25" W x 13.5" H x 2.5" DLetters, documents, thin mailers
Small25" W x 13.5" H x 4" DPoly bags, small boxes, pharmacy
Medium25" W x 13.5" H x 7.5" DEveryday e-commerce boxes
Large25" W x 13.5" H x 11.5" DBulk household orders
X-Large25" W x 13.5" H x 19" DMulti-item and oversize boxes
Quarter Panel25" W x 13.5" H x 35" DLong or awkward parcels
Half Panel25" W x 13.5" H x 73" DThe largest items the system accepts

How system size follows community size

The number of residences helps us choose a locker size. We confirm the recommended length and number of compartments during the property review.

View reference sizing table
Apartment unitsSystem lengthApprox. compartments
1-606 ft46
61-8012 ft68
81-11015 ft91
111-15021 ft117
151-18024 ft140
181-21027 ft163
211-24030 ft186
241-27033 ft209
271-30039 ft235
301-33042 ft258
331-36045 ft281
361-40051 ft307
401-43054 ft*330
431-46057 ft*353
461-49060 ft*376
491-52063 ft*399
521-55069 ft*425
551-58072 ft*448

Sizes are Amazon's estimates and can shift with the building layout. The largest single Locker run is 51 feet, so any recommendation above that (marked *) is installed as more than one system.

Indoor vs. outdoor

Amazon Hub Lockers can go indoors or outdoors. The team reviews the property details and proposed locations, then recommends the best setup.

Indoor Amazon Hub Lockers system along a resident lounge wall

Indoor Apartment Locker

Height
6'-9" structure plus 3" clearance above (7'-5" with the cellular modem option)
Depth
25" total system depth; 5'-1" minimum depth including front clearance
Shape
Straight, L or U layout
Side clearance
2" per side
Front clearance
36" (48" in California)
Back clearance
1-2" behind the system for air flow
Power
Standard duplex outlet, 125W max, 7 ft above the finished floor; a new circuit is needed if the load exceeds 3.0A
Connectivity
Cellular modem option; a data port is only needed where cellular speeds fall below 1 mbps up or down
Mounting
Two or more interior anchors per section under 18 ft, provided by Amazon
Outdoor Amazon Hub Lockers installed on a concrete pad

Outdoor Apartment Locker

Height
7'-0" structure plus 5" for the cellular antenna; 7'-5" clearance
Depth
25" total system depth; 5'-7" minimum depth including front clearance
Weatherization
Weatherized, with a drainage system and integrated lighting, no shelter needed
Side clearance
8" per side for bracing brackets (8" on all four sides if freestanding)
Front clearance
36" (48" in California)
Back clearance
5" from any wall or structure for air circulation
Power
Hard-wired 120V AC @ 60Hz 8.0A, 20A dedicated circuit, 840W max (125W typical), with a disconnect beside the system
Connectivity
Cellular; a data port is only needed where cellular speeds fall below 1 mbps up or down
Mounting
Bolted to a poured concrete pad, never asphalt, with final hookup by a licensed electrician

Finish: Squid Ink (Pantone 432C). One standard finish across indoor and outdoor systems, with Amazon branding on the tower.

What a site needs depends on the existing conditions. Indoors that is typically a standard duplex outlet (125W maximum, 7 ft above the finished floor), with a new circuit only where the load exceeds 3.0A; interior anchors are included with the system. Outdoors it is a concrete pad, a dedicated 20A circuit with a disconnect, and final hookup by a licensed electrician. If permits are required, our team handles the permitting process for the community.

Community Branding Upgrade (optional, paid)

Through the paid Community Branding Upgrade, the tower can be finished in a community's own colors, logo or architectural design instead of the standard finish. Artwork is prepared to the branding guidelines and submitted for Amazon approval. It is then produced and installed alongside the locker system as part of the project. Branding may not imply Amazon endorsement or association. Wraps are quoted individually once the final system length and placement are confirmed.

  • All artwork is submitted for Amazon approval before production.
  • The community logo sits on a solid background color.
  • Hub by Amazon branding, the friendly name, and the customer-service number stay clearly readable.
  • No outside brands, paid advertising, or restricted-product imagery.

Where the locker can go

Placement is confirmed during the property review. These are the conditions our team looks for at each candidate location.

  • Within 150 feet of the existing USPS mailbox location
  • Indoor systems on the same floor as the mailboxes, or near the building entrance or lobby
  • Reachable by carriers and residents under the community's access arrangement, with extended access considered where the property allows
  • Flat, stable concrete, no more than a 2" rise or fall across the slope
  • Clear of fire alarms, emergency shutoffs, thermostats, utility access, and drain covers
  • Not sharing a circuit with compressor equipment such as vending machines
  • 60" turnaround radius where the system sits in a room or at a sidewalk edge
  • Outdoor systems at least 5 feet from propane tanks or other combustible items, and away from drive lanes

Final system sizing, pricing, site requirements and availability are confirmed after the property review.